Energihushållning och varsamhet för äldre byggnader : Chefsbostaden i Strömsholm, ett timmerhus från 1900-talets början

This report is the result of a degree project in building engineering, at an advanced level. The project evaluated a building from a technical and historical point of view, and focused on its energy consumption, particularly the energy used for heating. The building in question was a small apartment building in Strömsholm, Sweden. It was made in 1902, from vertical logs, a not so common form of the traditional log house. The goal of the project was to evaluate if the energy consumption could be reduced in accordance with building preservation regulations, that is without damaging any of the building?s cultural or historical values.The building was surveyed with the help of archive and literature studies, interviews and inspections.

En jämförelse mellan vakuumisolering och traditionell isolering

The purpose of this thesis is to investigate if vacuum insulation panels are a competitive alternative to traditional insulation.Vacuum insulation has been used as insulation in buildings in Germany and Switzerland for a few years. In Sweden the high-performance insulation material is mainly used in refrigerators, freezers and vacuum thermoses. The development is proceeding well and vacuum insulation is becoming more common in the construction industry. Since it is a relatively unexplored material on the market there are many flaws and problems with the material.The questions we have chosen to answer in this report include an increased knowledge of vacuum insulation, various problems that may arise when handling/installation and the pros and cons of vacuum insulation compared to standard traditional insulation.The methods we have chosen to use in this report is a literature study, interviews with various suppliers and manufactures and calculations to show the differences between traditional and vacuum insulation. Vacuum insulation is 5-10 times better insulation than standard traditional mineral wool insulation, mainly at the beginning of its lifetime.Vacuum insulation panels (VIP) have a service life of approximately 50 years, whereas traditional insulation has a service life of approximately 100 years.

Avvikelser i energiprestanda

Calculated and measured energy in residential buildings is going to differ. The reason to this may be due to many factors. In this study there is a study on how these factors affect the energy use in a building. To get an insight in what defines energy, there is first a description of energy supply both worldwide and used in Sweden, followed by a description of the energy balance. In this study energy will be studied in residential buildings only.

Användande av diffusionsspärr vid tilläggsisolering av äldre byggnader med trästomme

In the current situation a big part ofthe settlements that exist in Sweden isin need of renovation and energyefficiency in order to survive.Therefore, also many of the older houseswith a wooden structure are in a need ofenergy efficiency, which can be done ina variety of ways, including addinginsulation.This project deals with whether the useof a diffusion barrier or a vaporbarrier affects a wall structure byadding insulation to an older house witha timber frame. The insulation materialswhich are concidered in thisinvestigation are mineral wool and woodfiber insulation. Efforts are focused onthe effects of moisture on theseinsulation materials.To demonstrate the differences thatarise the moisture measurement programWUFI have been used to simulate avariety of wall designs. These designsare developed in consultation with theconstruction carers who are active inthe industry.Using WUFI graphs illustrating themoisture levels of the wall structureswere obtained and from these conclusionsvould be drawn. The work demonstratesthe differences that arise when using adiffusion barrier or vapor barrier inwall construction.

Montering av isolering på vattentank

One of today problem at IVT industries would be assembly of insulation on water cisterns. The element of assembly insulation on the cistern gets too elevated; hence one has to climb onto the stand the cistern is assembly on. This will increase the risk of work related injuries when there is a risk of falling down. It?s also rather strenuous on shoulders due to work with your arms high above your head.

Analys av fördelningssystem för bostadshus

The purpose of this project is to analyze earthing systems for houses. By practical measurements and theoretical analyzes consequences of possible faults, that can occur within the facility and in the low-voltage distribution network, is illustrated.  The reason for this project is that nowadays one has to arrange with a main equipotential bonding system for buildings. Apart from that, if necessary, bathrooms must be provided with a supplementary equipotential bonding system.The practical measurements verify that potential differences in facilities may be due to voltage drops in the PEN conductor between the origin of the electrical installation and the power transformer.Based on the theoretical analyzes of possible faults, it is considered that the requirement for  supplementary equipotential bonding systems for bathrooms in most cases can be questioned, when basic insulation, fault protection, residual current devise and main equipotential bonding system already provides an adequate level of protection.A PEN conductor loss may result in a situation where metallic parts attached to the equipotential bonding system starts working as earth electrodes. Equipotential bonding system may also increase the incidence of stray currents. If TN-C-S systems is provided with a local connection to earth a redundant system against PEN conductor loss is obtained.

Energieffektivisering av arbetsbodar på byggarbetsplatser

Everyone has to take a greater responsibility in energy issues, both individuals and companies. There have been some major developments in the construction industry but there is still a lot to be done. This diploma work thesis presents different methods of making existing construction shed establishments to use less energy. What is possible to do and how much energy is there to be saved? A shed establishment consisting of 8 shed units were studied in this project and the building simulation tool VIP-Energy was used to simulate different types of material in the sheds. An infrared camera was used to locate thermal bridges. There are several factors that can be improved to make a construction shed establishment to use less energy.

Jämförelse av stenull- och polyuretanisolering : Brand- och fuktegenskaper i passivhuskonstruktion

This report compares two different types of insulation with regards to fire and moisture. The materials were tested for the company Fiskarhedenvillan AB, for a wall and a roof construction that the company currently uses in the establishment of Sweden's first certified passive house for international standards.Their current material, Rockwool, is compared to a relatively new material on the Swedish market called SEALECTION Agribalance sold by the company ISO Green AB. The material is a type of polyurethane insulation. This insulation material would result in a more efficient execution of the construction as it provides waterproofing and is applied more easily than Rockwool. From a fire standpoint, literature studies and discussions with fire experts led to results.

Vakuumisolering ? Ekonomiskt försvarbart för småhus?

The number of people in the world and the urbanization increases. This leads to a bigger need of space for the built environment, space that soon doesn?t exist. A large portion of humanity?s energy disposal is used for heating of buildings.

Verktyg för tillskärning av nätisoleringsmatta : Produktutvecklingsprojekt för en effektivare och mer användarcentrerad metod för tillskärning av nätisoleringsmattor

This report covers a product development project conducted as Bachelor of Science thesis forthe Innovation & design engineer program at Karlstad University.The assignment was supplied by MMB Consulting, Kristinehamn. The purpose of this projectwas to find an alternative way of shaping wire-net insulation mats. This insulation product isused for fire and thermal insulation of technical installations. The insulation consists of stoneor glass wool with a sewn on steel wire netting on the out facing side. This netting has thepurpose to enable fastening to e.g.

Grinda Wärdshus : Hållbara Isoleringsmöjligheter förVandrarhemmet på Grinda

pelago. There is an old inn that is located on the island that has become a very popular attraction in the last couple of years. The inn has both a well-known restaurant as well as conference facilities that are used by tourists as well as the people of Stockholm over the summer months. The inn was built 1908 and has since remained in the same condition.make islands in the archipelago more environmentally friendly and promote sustainability. One of their project islands is Grinda.

Betydelsen av hästens hud och päls för reglering av kroppstemperatur i kyla ? vad händer vid klippning och täckning?

The horse is a homeothermic animal and to keep a constant body temperature in winter season is important. Acclimatisation is to provide means for a good thermal insulation consisting of skin, hair, and an outer air layer. The skin covers the horses body and it is composed of three main layers where the top layer of the epidermis consists of dead keratinized cells that are constantly being sheed. The dermis is composed of collagen connective tissue that give the skin its strength. The bottom layer with subcutaneous fat provides a thermal insulation and can be used as an energy reserve in cold weather.

Skalkonstruktion : Med inriktning mot hållfasthet och dämpning av ljud

The sound part is mainly practical and is dependent on concepts that have been tested through measuring with a sound level meter. The design part is more theoretical and has been verified with CAD models and finite element analysis.With a sound damping hood on the compressor the sound level is reduced with up to four dB. An optimized absorbent for the compressor space gives a reduction with three dB. By using the insulation for the heat water tank as absorbent we can see a sound reduction on the lover octave bands. A reduction like this is elsewhere hard to achieve as at it requires thick absorbents.By changing the today?s insulation to the heat water tank to a form of polystyrene polymer insulation the weight from the heat pump above can be transferred to the stable heat water tank.

Optimering av UA-Värde : Förbättring av en containerkonstruktion

Envirotainer builds containers that are specialized in transporting of temperaturesensitive products these containers are customized for airplanes. The containers arethen leased to other companies, most often to pharmaceutical companies.Envirotainer are based in Lagga, Knivsta. It is also here where the production of thecontainers is held. The container RAP T2 was designed in the early 80ies. The RAPT2 contains a fleet of about 1220 containers spread all over the world.

Tilläggsisolering - lönsamt enligt en livscykelkostnadsmodell?

It is found that the properties of the record years of 1965-1975 is leaking a lot of energy andthese properties are facing a major energy efficiency. From the energy aspect, the facade isafflicted with poor thermal insulation which is a big problem. To address this problem addinginsulation is a good alternative to reduce overall energy consumption of a building. Thewindows on these buildings are also a problem from the energy point of view. Therefore,there are many reasons considered for energy upgrading.